...
Interaction Configuration
The component has the following attributes mentioned below which can be configured from its Configuration Property sheet (CPS). Figure 1 illustrates the panel.displays the CPS with Binary Output Required property disabled, and Read input from file and Read output to file properties enabled.
Figure 1: Configurable properties for Encryption component
...
The individual configurations are similar to that of Data Encryption Details.
Binary Output Required
Enable this property if Binary Output is needed. Else encrypted data will be in XML format.
Note |
---|
When this property is enabled, properties other than Only Sign Data and Read input from file mentioned below are not applicable. |
Encode Data
Encode Data after encrypting using the Base64 encoding scheme, This option will help in avoiding characters of encrypted data included in the output XML generated if the Binary Output option is not selected.
Only Sign Data
Check this option if the data has to be only signed without Encrypting.
Input to Encryption component can be in XML format. The XML format is shown in Figure 4. The values of Encryption Algorithm Parameters and Digest Parameters can be mentioned or else these values are taken from cps.
Read Input From File?
Choose this option to read input from a file instead of the component input port.
Input File Directory
Directory The absolute path of the directory where the input file is located.
Input File Name
Name of the Input File.
Write output to File?
Select this option if the output is to be written into a file.
Output File Directory
Directory The absolute path of the directory where the output file needs to be stored.
Output File Name
Name of the output file.
Action if same file exist
If the file with same name exists in the target folder, choose the action to be taken from the below options:
- Overwrite: Overwrites the existing file and hence the old file gets replaced with the new one.
- Rename: Renames the file with "filename + MMddyyHHmmss + counter(optional)".
Hex Output Required
Enable if a Hex string output is required.
Delimiter
Messages get encoded based on the delimiter configured.
The Hex string delimiter can be chosen from ("", " ", "0x", "0X", "\0x", "\0X", "\x", "\X").
Hex Input Required
Enable if a Hex string input is required.
Monitoring Configuration
Please refer to the Monitoring Configuration section in Common Configurations page.
Expert Properties
Enable the Expert Properties view to configure these properties.
...
Refer to the Target Namespace section under the Common Configurations page.
Monitoring Configuration
Please refer to the Monitoring Configuration section in Common Configurations page.
Testing
Sample input
Figure 9: Sample Input
...
Documentation of the scenario and instructions to run the flow can be found in the Help tab of the flow present in eStudio.