- In the Server Explorer pane, right-click the FMQ-JMX node, and click the Copy option.
- Right-click the Servers node and click the Paste option.
- Rename the new FMQ-JMX_1 to StandAloneRepeater.
- In the properties window, change the RMIConnector's ConnectorPort to 2059.
Adding a Link
The administrator can create new replication links dynamically. This enables the applications to replicate messages on topics that are created after the repeater has started. Information such as the name of the link name, the source and target servers between the link, the protocol to be used for connection and login information, need to be provided when a new link is added to the repeater. To add a new link, follow the steps below:
- Run the FMQ Server and run the StandAloneRepeater.
- From the Server Explorer pane, login into StandAloneRepeater.
- Navigate to Fiorano > Repeater > RepeaterManager > FioranoRepeaterManager and select the FioranoRepeaterManager node.
- Right-click and select the addLink(LinkConfig) from the drop-down menu. The Invoke addLink(LinkConfig) dialog box is displayed.
Click the editor button of parameter LinkConfig. The addLink(LinkConfig) – LinkConfig dialog box is displayed.
Enter all required details. These include:
View Operations option.
- The Invoke Operation dialog box is displayed. Click the addLink(LinkConfig) parameter in the left.
Enter all required details and click the addLink button under the Invoke Operation section.
Tip Refer the following table for descriptions for parameters.
Parameter
Default value
linkName
Link-1
sourceServerName
FMQ
sourceServerPassword
anonymous
sourceServerProtocol
TCP
sourceServerSecurityManager
Repeater
sourceServerURL
http://localhost:1856
sourceServerUserName
anonymous
targetServerName
FMQ
targetServerPassword
anonymous
targetServerProtocol
TCP
targetServerSecurityManager
Repeater
targetServerURL
http://localhost:1856
targetServerUserName
anonymous
- Click OK and Invoke the operation.
- Close the addLink operation dialogue box.
Adding a Link Topic
It is possible for the administrator to add one or more link topics to an existing topic. To add a link topic to an existing topic information such as the source topic name, the target topic name and the message selector need to be provided. To add a link topic follow the steps below:
- Navigate to Fiorano > Repeater > Link, right-click the mouse and click the Refresh option; a link gets added.
- Click the link displayed and select RepeaterLink MBean as shown in the figure below.
- Right-click the RepeaterLink MBean and select operation addLinkTopic(LinkTopicConfig). The Invoke addLinkTopic(LinkTopicConfig) dialog box is displayed.
Click editor button of parameter LinkTopicConfig. The the View Operations option. - Click the addLinkTopic(LinkTopicConfig) - LinkTopicConfig dialog box is displayed option.
- Fill Specify the required parameters , click OK and then click Invoke.and click the addLinkTopic button under the Invoke Operation section.
Adding a Reply Topic
It is possible for the administrator to add one or more reply topics to existing topics. To add one or more reply topics to existing topics information such as the source topic name, the target topic name and message selector need to be provided. To add a Reply topic, follow the steps below:
- Navigate to Fiorano > Repeater > Link > (LinkName) and select theRepeaterLink MBean.
- Right-click the RepeaterLink MBean and select operation addReplyTopic(ReplyTopicConfig). The InvokeaddReplyTopic(ReplyTopicConfig) dialog box is displayed.the View Operations option.
Click the editor button of the parameter ReplyTopicConfig. The addReplyTopic(ReplyTopicConfig)- ReplyTopicConfig dialog box is displayed.
- Specify the properties and click the OK button and Invoke the operation.
- Specify the parameters and click the addReplyTopic button under the Invoke Operation section.
Removing a Link
The administrator needs to follow the steps below to remove links from a repeater:
- Navigate to Fiorano > Repeater > RepeaterManager > FioranoRepeaterManager and select the FioranoRepeaterManager node.
- Right-click the FioranoRepeaterManager node, click the View Operations option and select operation removeLink(LinkName). The InvokeremoveLink(LinkName) dialog box is displayed.
- Specify the parameters and click the removeLink button under the Invoke Operation section.
- Specify the link name and click Invoke button.
...
- The administrator needs to follow the steps below to remove a link topic from the repeater. Navigate to Fiorano > Repeater > Link > (LinkName) and select the RepeaterLink MBean.
- Right-click the RepeaterLink MBean and select removeLinkTopic(LinkTopicConfig).
- Other steps are similar to the addLinkTopic.
...
- Navigate to Fiorano > Repeater > Link > (LinkName) and select the RepeaterLink MBean.
- Right-click the RepeaterLink MBean and select removeReplyTopic(ReplyTopicConfig).
- For additional steps please refer to addReplyTopic.
...
- Navigate to Fiorano > Repeater > RepeaterManager > FioranoRepeaterManager and select right-click the FioranoRepeaterManager node.
- Right-click the FioranoRepeaterManager node Click the View Operations button and select findDurSubscriptionInfo().